The new IPERJET DF filter equipped with horizontal cartridges is suitable for suction and filtration of welding fumes, fine and coarse dusts as well as of small quantities of chips, dusts/fumes from thermal cutting. It is a filter unit to be installed inside the work premises. If allowed by local regulations, the filtered air can be recycled into the working area giving a considerable energy saving.
The filter unit consists of one pre-chamber where the most dust is sorted out, falling then in the first collecting bin. The following labyrinth together with the high efficiency filtering cartridges and the second collecting bin complete the filtration of the remaining dust. The high-performance fan, placed just on the top of the unit assures a high suction capacity and a low noise level
|
|
1. Dirty air intake |
|
|
|
|
|
Optional |
Code: 50831012
|
Clean Air Outlet Filters |
|
|
|
Code: 50831011
|
|
|
|
|
Code: 50101540
|
Technical Specifications ■Electrical control panel (standard for DF9, optional for DF4 and DF6) ■Sound absorbing plenum (optional) |
|
|
Dimensions | IPERJET | A | A1 | B | C | D | E | F | G | H | I | L | M |
DF4— DF4 Thermal cut | 930 | 1120 | 1610 | 1915 | 1015 | 1210 | 2085 | 2043 | 866 | 838 | 433 | ||
DF6— DF6 Thermal cut | 1100 | 1315 | 1805 | 2130 | 1190 | 1210 | 2260 | 2358 | 1038 | 840 | 553 | ||
DF9— DF9 Thermal cut | 1500 | 1495 | 1979 | 2354 | 1293 | 2540 | 2532 | 1293 | 980 | 553 |
Filter |
DF4 - DF4/R | Thermal Cutting | ||||||
IPERJET | DF6 | DF9 | DF4 - DF4/R | DF6 | DF9 | |||
Cartridge quantity | 4 | 6 | 9 | 4 | 4 | 6 | ||
IFA/BGIA class | M PES | M—PES+PTFE MEMBRAN | M—NANOTECH | |||||
(Standard) Polyester | Polyester Teflon membrane | Cellulose with Nanofiber | ||||||
Cartridge dimensions | Ø325 - H750 mm | Ø325 - H750 mm | Ø325 — H660 mm |
DF4-DF4/R | DF6 | DF9 | |||
IPERJET | 3HP-37 m² | 4HP-48 m² | 5,5HP-72m² | 10HP-108 m² | |
Filtre Yüzeyi | |||||
IPERJET THERMALCUT M- PES+PTFE/MEMBRAN | 3HP-48 m² | 4HP-48 m² | 5,5HP-72 m² | ||
IPERJET THERMALCUT M-NANOTECH |
3HP-84 m² | 4HP-84 m² | 5,5HP-126m² | ||
Kod | 50834122 | 50834230 | 50834322 | 50836140 | 50836330 | 50839140 | 50839340 |
IPERJET | DF4 | DF4/R | DF4 THERMAL | DF6 | DF6 THERMAL KESİM | DF9 | DF9 THERMAL |
KESİM | KESİM | ||||||
Engine power | 3HP-2,2 kW | 4HP-3 kW | 3HP-2,2 kW | 5,5HP-4 kW | 4HP-3 kW | 10HP-7,5 kW | 5,5HP-4 kW |
Rpm | 2865 | 2895 | 2865 | 2900 | 2895 | 2915 | 2900 |
Fan type | PRA250 | PRA280 | PRA250 | PRA320 | PRA280 | ||
Fan power supply | 230/400V 50 Hz | 400/690V 50 Hz | 230/400V 50 Hz | 400/690V 50 Hz | |||
optional 60 Hz. can be made. | |||||||
Nominal air flow rate | 2200 m³/h | 3000 m³/h | 2000 m³/h | 4000 m³/h | 2500 m³/h | 6500 m³/h | 3500 m³/h |
Usable static pressure | 100 m H₂O | ||||||
Approximate noise level | 78dB-71dB* | 78dB-71dB* | 77 dB-70dB* | 81 dB-75 dB* | 77 dB-70 dB* | 87 dB-79 dB* | 79 dB-73 dB* |
Power tank capacity | 80+86 Lt 90+115 Lt | 102+137 Lt | |||||
Weight | 380 kg | 385 kg | 380 kg | 470 kg | 620 kg | ||
Compressor pressure | 5/6 BAR | ||||||
Valve supply | 24 VDC |