Orhangazi Mahallesi ISISO Sanayi Sitesi 19. Yol Sokak P Blok No:2 Esenyurt 34519 İstanbul

Arama Yap
TR EN
Cleaning DF and Jetclean DF

The new IPERJET DF filter equipped with horizontal cartridges is suitable for suction and filtration of welding fumes, fine and coarse dusts as well as of small quantities of chips, dusts/fumes from thermal cutting. It is a filter unit to be installed inside the work premises. If allowed by local regulations, the filtered air can be recycled into the working area giving a considerable energy saving.
 

The filter unit consists of one pre-chamber where the most dust is sorted out, falling then in the first collecting bin. The following labyrinth together with the high efficiency filtering cartridges and the second collecting bin complete the filtration of the remaining dust. The high-performance fan, placed just on the top of the unit assures a high suction capacity and a low noise level
 

GET AN OFFER
Technical Details

 

 

 

 

1. Dirty air intake
2. Separator filter
3. Powder tank
4. Second powder tank
5. Second stage filter
6. Fan
7. Cartridge filters
8. Compressed air tank
9. Fresh air outlet
10. Manometer - switch

 

   

 

 

 

                     Optional 

 

 

 

 

 

 

Code: 50831012
Input adapter




Code: 50831013
Input connection for arms


Code: 50831014
Input connection for arms

 

 

Clean Air Outlet Filters

 

 

 

 

 

 

 

 

 

Code: 50831011
Fresh air outlet adapter


Code:50831021
Vent (A)


Code: 50831022
Active Carbon (B)

Code: 50831023
Hepa (C)

 

 

 

 

 

 

 

 

 

 

 

 

Code: 50101540
Acrobat arm evolutions

 

 

 



Code: 50831046
Electrician controls Panel

 

 

 

Technical Specifications

Electrical control panel (standard for DF9, optional for DF4 and DF6)

Sound absorbing plenum (optional)

 

 

 

     

 

Dimensions  IPERJET A A1 B C D E F G H I L M
 DF4— DF4 Thermal cut 930   1120 1610 1915 1015 1210 2085 2043 866 838 433
 DF6— DF6 Thermal cut 1100   1315 1805 2130 1190 1210 2260 2358 1038 840 553
 DF9— DF9 Thermal cut   1500 1495 1979 2354   1293 2540 2532 1293 980 553

 

 Filter
Card

  DF4 - DF4/R     Thermal Cutting
IPERJET DF6 DF9 DF4 - DF4/R DF6 DF9
Cartridge quantity 4 6 9 4 4 6
IFA/BGIA class   M PES  M—PES+PTFE MEMBRAN  M—NANOTECH
(Standard) Polyester Polyester Teflon membrane Cellulose with Nanofiber
Cartridge dimensions  Ø325 - H750 mm  Ø325 - H750 mm  Ø325 — H660 mm

 

         
  DF4-DF4/R DF6 DF9
      IPERJET 3HP-37 m² 4HP-48 m² 5,5HP-72m² 10HP-108 m²
Filtre   Yüzeyi
   IPERJET   THERMALCUT     M- PES+PTFE/MEMBRAN 3HP-48 m² 4HP-48 m²  5,5HP-72 m²
 
   IPERJET THERMALCUT
 M-NANOTECH
3HP-84 m² 4HP-84 m²  5,5HP-126m²
 

 

Kod 50834122 50834230 50834322 50836140 50836330 50839140 50839340
IPERJET DF4 DF4/R DF4 THERMAL DF6 DF6 THERMAL KESİM DF9 DF9 THERMAL
KESİM KESİM
 Engine   power 3HP-2,2 kW 4HP-3 kW 3HP-2,2 kW 5,5HP-4 kW 4HP-3 kW 10HP-7,5 kW 5,5HP-4 kW
 Rpm 2865 2895 2865 2900 2895 2915 2900
 Fan type PRA250 PRA280 PRA250 PRA320 PRA280
 Fan power   supply 230/400V 50 Hz  400/690V      50 Hz  230/400V    50 Hz 400/690V 50 Hz
optional 60 Hz. can be made.
 Nominal air   flow rate 2200 m³/h 3000 m³/h 2000 m³/h 4000 m³/h 2500 m³/h 6500 m³/h 3500 m³/h
 Usable   static   pressure 100 m H₂O
 Approximate   noise level 78dB-71dB* 78dB-71dB* 77 dB-70dB* 81 dB-75 dB* 77 dB-70 dB* 87 dB-79 dB* 79 dB-73 dB*
 Power tank   capacity                           80+86 Lt                                                  90+115 Lt 102+137 Lt
 Weight 380 kg 385 kg 380 kg 470 kg 620 kg
 Compressor   pressure 5/6 BAR
Valve supply 24 VDC